--- title: "Wiring diagrams for tank monitoring" slug: "wiring-diagrams-for-tank-monitoring" updated: 2026-11-18T15:18:40Z published: 2026-11-18T15:18:40Z canonical: "docs.calculus.group/wiring-diagrams-for-tank-monitoring" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.calculus.group/llms.txt > Use this file to discover all available pages before exploring further. # Wiring diagrams for tank monitoring ## Digital Matter Hawk ### 4-20mA sensor Connecting a 4-20mA sensor using BD 18.605G or a 4-20mA plug-in board. **RS-1: BD 18.605G** #### Model: RS-1 - BD 18.605G wiring instructions - White wire (Voltage) → I/O2 +VBOOST OUT - Brown wire (4-20mA) → I/O9 4-20mA > [!WARNING] > Check the model! > > These wiring instruction are solely for model: RS-1. You can find your model type printed on the circuit bord. ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756802409863.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=swnz3OZkKytOTrRl5t7TY9Wh9agFLRkCskLp6UUKybM%3D) **4-20MA: BD 18.605G** #### Model: 4-20MA - BD 18.605G wiring instructions (multiple tanks) - Brown wire (4-20mA): sensor 1 → I/O1 - IN - Brown wire (4-20mA): sensor 2 → I/O3 - IN - Brown wire (4-20mA): sensor 3 → I/O5 - IN - Brown wire (4-20mA): sensor 4 → I/O7 - IN - White wire (Voltage) → I/O9 +VBOOST OUT Use a Wago clamp to connect the different cables. Attach the white cables of the different pressure sensors in this clamp, as well as a separate white cable that you will use for the voltage as listed above. > [!WARNING] > Check the model! > > These wiring instruction are solely for model: 4-20MA. You can find your model type printed on the circuit bord. ![Hawk plug-in board with labeled input and output connections for 4-20mA signals.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1761120530907.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=aP%2FLTdFZ3etVaO7D%2FhqOJTpVojsLOZnNT7AK5tw6fp8%3D) **Ratiometric sensor** > [!CAUTION] > Attention! > > The following information, regarding the 4-20mA sensor combined with Ratiometric sensor, is no longer applicable. We will try our best to provide you with the correct information as soon as possible. #### Ratiometric sensor wiring instructions (AdBlue tank) - Black wire (Voltage) → I/O2 +VBOOST OUT - Brown wire (4-20mA) → I/O9 4-20mA ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756802696179.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=MF4F5oQc0wT0mXGQ48XYS2XKEVcX1KMfH7wo4uFQ6rY%3D) #### Ratiometric sensor wiring instructions (Diesel tank) - Green wire (Data) → I/O1 AIN1 - Black wire (Voltage) → I/O5 +3.3V OUT - Brown wire (GND) → I/O6 SWGND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756803010345.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=Olg%2B8Wryjpo%2BChgW0soCY4QbpzbxIpsS3L63ht2W818%3D) ### Ratiometric Connecting a Ratiometric using BD sensor 5V, Huba sensor 3.3V or Keller sensor 3.3V. **Keller sensor 3.3V** #### Keller sensor 3.3V wiring instructions - Red wire (Data) → I/O1 AIN1 - Black wire (Power supply 3.3 V) → I/O5 +3.3V Out - White wire (GND) → I/O6 SWGND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756802172972.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=4rOIR%2Fnzvyp57lBzo82b2IZEH7q2NEUGlBa1%2B749sfg%3D) **BD sensor 5V** #### BD sensor 5V wiring instructions - Green wire (Data) → I/O1 AIN1 - White wire (Power supply 5V) → I/O2 +VBOOST OUT - Brown wire (GND) → I/O6 SWGND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756800434716.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=sPyr5FXYsvWY3MX3CMpjeIenlhTNXoxbv8Ef4vinob8%3D) **Huba sensor 3.3V** #### Huba sensor 3.3V wiring instructions - Green wire (Data) → I/O1 AIN1 - Brown wire (Power Supply 3.3V) → I/O5 +3.3V Out - White wire (GND) → I/O6 SWGND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756801739853.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=X9XA5K3K9cD0wHUozyIeNGKX8GpnVmrw57TTd3aqC3s%3D) **Rochester – Ratiometric** This Rochester sensor uses a **ratiometric voltage signal**, not a resistance (Ohm) measurement, to determine the tank level. It is connected to the Digital Matter Hawk via an AG-Tech-2 board. The wire colors differ depending on the sensor variant, but the connections remain identical. > [!WARNING] > Different Measurement Type > > If your Rochester sensor uses resistance measurement (Ohms), refer to the **Rochester – Ohmic** section under [**Other Applications**](/v1/docs/wiring-diagrams-for-tank-monitoring#other-applications). #### Rochester sensor - variant 1 wiring instructions - Green wire → I/O5 AIN1 - White wire → I/O9 +VBOOST OUT - Brown wire → GND #### Rochester sensor - variant 2 wiring instructions - White wire → I/O5 AIN1 - Red wire → I/O9 +VBOOST OUT - Black wire → GND | **Rochester sensor - variant 1** ![](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1794909501174.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=2ShqsrVpno91PYyrf7WR%2BY%2BP7TzzgpDGU79uFz6oBvA%3D) | **Rochester sensor - variant 2** ![](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1794909381628.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=W1%2F8j6UqXZg1f%2BS4Xi38dvLkw24Ct30mLCPD5jLBw6c%3D) | | --- | --- | ### Watermeter Connecting a watermeter using Reed switch or H2Q. **Reed switch** #### Reed switch wiring instructions - Green wire → I/O7 DIN1 - White wire → VIN ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756801042209.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=RI%2Bdqkqi82q3M3jrgZCSqyXn4kFtnpAJT5YmoIrARCs%3D) **H2Q** #### H2Q wiring instructions - Red wire → I/O7 DIN1 - Blue wire → GND - Black wire (Battery) → GND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756799942732.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=uf3gke6Lb4FE8lHYztcd%2FkGUGxRGvFiBed5v6ilUotI%3D) ### Other applications Connecting a Siemens MAG8000 Modbus, 1-Wire, 0-10V float switch or a Rochester sensor. **Siemens MAG8000 Modbus** #### Siemens MAG8000 Modbus wiring instructions - White wire (GND) → I/O3 RS-485 B - Brown wire (Data) → I/O4 RS-485 A - Black wire (GND) → GND - Red wire (Battery/Power supply 12-24V) → VIN ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756887818331.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=lNK7vacHnwOXYxbyxmWoQHMTDZ24DCQUDPXzI8KGxjo%3D) **1-Wire** #### 1-Wire wiring instructions - Green wire (Voltage) → I/O5 - White wire (Data) → I/O 8 - Brown wire (GND) → GND ![Hawk plug-in board model RS-1 with various input and output connections labeled.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1756803453480.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=Z8EBQewNF%2F%2BnpukA4FIKL5QiEvxwJzZWgkidMAW0Ji4%3D) **Float Switch 0-10V** #### Float switch: 0-10V wiring instructions > [!WARNING] > Attention! > > Calculus has provided the plug-in board with resistors. Don’t remove them from the plug-in board, even when you’re connecting the sensors. > > The resistors, their wires and the heat-shrink tubing aren’t allowed to touch each other. If they do, you will cause a short circuit. Only the part of the wires that are twisted together by Calculus, is allowed to touch each other. > > Don’t connect your sensors to the plug-in board while the power is connected. - Black wire (GND) → I/O1 SWGND - Blue wire (sensor 1) → I/O5 AIN1 - Blue wire (sensor 2) → I/O6 AIN2 - Blue wire (sensor 3) → I/O7 AIN3 - Blue wire (sensor 4) → I/O8 AIN4 ![](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1764340862351.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=6N6zyapLwgfY9B6qpHmWfj0WaBfaGo4u9MOLb8GHfjA%3D) **Rochester – Ohmic** This Rochester sensor uses **resistance measurement (Ohm)**, not a ratiometric voltage signal, to determine the tank level. The electrical resistance varies with the liquid level and is measured through an analog input on the Digital Matter Hawk. > [!WARNING] > Different Measurement Type > > If your Rochester sensor uses a ratiometric voltage signal, refer to the **Rochester – Ratiometric** section under [**Ratiometric**](/v1/docs/wiring-diagrams-for-tank-monitoring#ratiometric1). #### Rochester sensor wiring instructions - Black wire (GND) → I/O1 SWGND - Black wire (fuel sensor) → I/O5 AIN1 - Black wire (adBlue) → I/O6 AIN2 ![](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1794908355398.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=k2HIeGdapMILTVniszQJVyB0xkt%2BFYiIqyirvhxNuog%3D) ## Digital Matter Eagle Connecting the supplied sensor to the gateway. #### Supplied sensor wiring instructions - White wire (Vs+) → VOUT (right side of the module) - Brown wire (Vs-) → 4-20mA 1 (left side of the module) ![](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1760534378841.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=5cMKEI%2B0JGcaQVyXWoqu8SxEe0GmvpUI3RmhcjliIp8%3D) ## Digital Matter Falcon Connecting the BD or HUBA sensor to the gateway. **BD sensor** #### BD sensor wiring instructions - Green → A-IN1 - Brown → GND - White → 3.3V ![Energizer batteries installed in a Falcon device with visible connections and indicators.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1760536665533.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=99qfbxQrmxj69fIsc5rM5J0XNb3eZSX%2BrlgqFg5ZMWo%3D) **HUBA sensor** #### HUBA sensor wiring instructions - Green → A-IN1 - White → GND - Brown → 3.3V ![Energizer batteries installed in a Falcon device with visible connections and indicators.](https://cdn.document360.io/94d0a983-5058-4b02-8d06-1228a999a7a1/Images/Documentation/image-1760537231902.png?sv=2026-02-06&spr=https&st=2026-11-20T03%3A31%3A00Z&se=2026-11-20T04%3A31%3A00Z&sr=b&sp=r&sig=wr7LF39Aq8KAu0cU8dte85ihRZw637K4tRBL%2FdlJp8Q%3D)